Previous image
Meiji MT6000 Series
Next image
Zoom image

Meiji MT6000 Series

Meiji Techno's new laboratory grade upright microscopes are the new MT6000 Series Biological with Epi-Fluorescence. The MT6000 Series employs Meiji Techno's all new ICOS™ (Infinity Corrected Optical System) making the study of mounted specimens fast and easy while delivering an excellent cost-to-performance ratio.

The MT6000 Series microscopes are configured for brightfield and epi-flourescence but can also be outfitted with optional phase contrast, polarized light and darkfield components. System modularity makes purchase and operation very affordable for colleges, universities, researchers and clinics.

Made In Japan

Model
Head
Illumination
Eyepieces
Objectives
Stage
Condenser

MT6200H

Binocular
Incident 100W Mercury + Transmitted Koehler 30W halogen
 
SWH10x FN22
U.Plan 4x, 10x, 40x, 100x oil
Fixed flat-top left or right-handed controls
Abbe NA 1.25 with iris in dovetail mount

MT6200EH

Ergonomic Binocular

MT6300H

Trinocular

MT6300EH

Ergonomic Trinocular
    • 10% off
    $15645.00, save $1564.50
  • $14080.50
Qty:  
In stock (1000 items available)
Add a different product to compare
    • Weight
      39.0000 lbs
    • SKU
      MT6000 Series
  • Meiji MT6000 Series Options
    P/N: MT6200H: Binoc. SWH10x E.P. 30mm O.D., F10x,F20x,F40x,F100x Plan S-Apo Obj., Flat-top Stage, Abbe 1.25, 100W Epi-Fluorescent & 30W (H) Illum., P/N: MT6200EH: Ergo. Binoc. SWH10x E.P. 30mm O.D., F10x,F20x,F40x,F100x Plan S-Apo Obj., Flat-top Stage, Abbe 1.25, 100W Epi-Fluorescent & 30W (H) Illum., P/N: MT6300H: Trinoc. SWH10x E.P. 30mm O.D., F10x,F20x,F40x,F100x Plan S-Apo Obj., Flat-top Stage, Abbe 1.25, 100W Epi-Fluorescent & 30W (H) Illum., P/N: MT6300EH: Trinoc. SWH10x E.P. 30mm O.D., F10x,F20x,F40x,F100x Plan S-Apo Obj., Flat-top Stage, Abbe 1.25, 100W Epi-Fluorescent & 30W (H) Illum.

Included:
   • MT6200H: Binocular Epi-Flourescence /Brightfield Compound Microscope with Quintuple Nosepiece and 100W Mercury light source and 30W Halogen Koehler illumination.
   • MA879/05: CHROMA filter-AT-GFP/FITC longpass-19002 mounted in Meiji Filter cube, Exciter(EX) AT480/30x, Dichroic (BS)AT505DC, Emitter(EM)AT5151p (Factory Installed)
   • MA880/05: CHROMA filter-AT-TRITC/Cy3 Longpass-19004 mounted Meiji filter cube, Exciter (EX)AT540/25x, Dichroic (BS)AT565DC, Emitter(EM)575lp (Factory Installed)
   • MA881/05: CHROMA filter-AT-DAPI/Hoechst/AlexaFlour 350-3900 mounted in Meiji filter cube, Exciter (EX):AT375/28x, Dichroic (BS):AT415DC, Emitter (EM):AT460/50m (Factory Installed)
   • MT-FL: Modular six position Epi-Fluorescent illuminator attachment with six positions for filter cubes, Includes one Blue Excitation excitation filter cube, one Green Excitation cube, one U Excitation and 3 empty filter cube positions for MA867
   • FL-LHJ: Lamphouse for use with 100W mercury lamp D.C. Arc lamp includes multi-lens achromatic collector and trigger wire
   • FL-PWJ: D.C. Power Supply (This power supply is for the 100W Mercury lamp only)
   • MA860: ND25 Neutral Density filter, 29.8mm diameter
   • MT-RF47: UV Eye protection filter
   • MA815: Binocular head-Siedentopf type, I.P. adjustment 53mm to 75mm, graduated diopter on left eyetube (30.0mm I.D. eyetube).  Inclined at 30 degrees, Inverted image
   • MA817 (x 2): SWH10X Widefield high eyepoint eyepiece, Field No. 22, tube O.D. 30.0 mm
   • MA844: Plan Semi Apo Objective F10X, N.A.0.40, W.D.1.0 mm, F.N.24
   • MA845: Plan Semi Apo Objective F20X, N.A. O.65, W.D. 0.7 mm, F.N.24
   • MA847: Plan Semi Apo Objective F40X, oil, N.A. 0.85, W.D. 0.2 mm, F.N.24
   • MA848: Plan Semi Apo Objective F100X oil, N.A. 1.25, W.D.0.2mm, F.N.24
   • MA700: Immersion oil
   • MA910: Abbe condenser, N.A.1.25 with iris diaphragm and dove tail mount
   • MA856/05: LB100 Blue Clear filter, 44.0mm diameter, unmounted
   • MA918R: Ceramic coated flat-top stage, 190mm x 149mm, with 80mm x 52mm X-Y movement, with right hand drop down coaxial controls
   • MA598: Attachable finger assembly for MA918R and MA918L
   • MA326: 6V 30W Halogen lamp (Factory Installed)
   • MA327: 3 Amp Fuse for Halogen illuminator
   • BA005: HBO 100W Mercury lamp (2200 Lumens, life expectancy 200 hours)
   • MA809/10: Removable AC Electric cord with plug (115V)
   • MA906 (x 2): Rubber Eyeshield for MA817 SWH10X eyepiece (Factory installed)
   • MA714: Dust Cover for MT6000 Series

OPTIONAL COMPONENTS & ACCESSORIES BELOW

Viewing Heads:
   • MA816: Trinocular head - Siedentopf type, I.P. adjustment 53mm to 75mm, graduated diopter on left eyetube (30.0 mm I.D. eyetube). Inclined at 30 degrees Inverted Image (Included in Model MT6300H)
   • MA957: Ergonomic tilting binocular head - Adjustable vertically from 10 to 50 degrees (30.0 mm I.D. eyetube) Erect image (Included in Ergonomic Model MT6200EH & MT6300EH)

Photo/Video Attachment:
   • MA958: Photo / video attachment with sliding 80/20 beam-splitter. For use with video or digital cameras when MA957/05 ergonomic head is used (Included in Ergonomic Model MT6300EH)

Eyepieces:
   • MA818: SWH 15X Widefield high eyepoint eyepiece, Field No. 16.0, tube O.D. 30.0 mm (each) (19mm reticle mount)
   • MA819: SWH 20X Widefield high eyepoint eyepiece, Field No. 12.0, tube O.D. 30.0 mm (each) (19mm reticle mount)
   • MA859: SWH 10X-F Focusing eyepiece with reticle mount (without reticle), tube O.D. 30.0 mm (each) (25mm reticle mount)

Plan Semi Apochromat Objectives for Fluorescent Microscopy:
   • MA982: Plan Apochromat Objective F40X, N.A. 0.80, W.D. 0.2 mm, F.N. 24, FL

Plan Apochromat Phase Objectives for Fluorescent Microscopy:
   • MA1012: Plan Apochromat Objective F4X, N.A. 0.13, W.D. 17.5 mm, F.N. 24
   • MA980: Plan Apochromat Objective F10X, N.A. 0.30, W.D. 8.6 mm, F.N. 24
   • MA981: Plan Apochromat Objective F20X, N.A. 0.65, W.D. 0.7 mm, F.N. 24
   • MA982: Plan Apochromat Objective F40X, N.A. 0.80, W.D. 0.2 mm, F.N. 24, FL
   • MA983: Plan Apochromat Objective F100X oil, N.A. 1.25, W.D. 0.2 mm, F.N. 24

Plan Semi Apochromat Objectives - Brightfield Objectives:
   • MA830: Plan Semi Apo Objective 2.5X, N.A. 0.07, W.D. 5.7mm, F.N. 24
   • MA831: Plan Semi Apo Objective 4X, N.A. 0.10, W.D. 17.8 mm, F.N. 24
   • MA832: Plan Semi Apo Objective 10X, N.A. 0.25, W.D. 10.7 mm, F.N .24
   • MA833: Plan Semi Apo Objective 20X, N.A. 0.40, W.D. 7.29 mm, F.N. 24
   • MA834: Plan Semi Apo Objective 40X, N.A. 0.65, W.D. 0.5 mm, F.N. 24
   • MA837: Plan Semi Apo Objective 100X oil, N.A.1.25, W.D. 0.23 mm, F.N. 24

Plan Semi Apochromat Objectives - Phase Objectives:
   • MA839: Plan Semi Apo Phase Objective 10X, N.A. 0.25, W.D. 10.7 mm, F.N. 24
   • MA840: Plan Semi Apo Phase Objective 20X, N.A. 0.40, W.D. 7.29 mm, F.N. 24
   • MA841: Plan Semi Apo Phase Objective 40X, N.A. 0.65, W.D. 0.5 mm, F.N. 24
   • MA842: Plan Semi Apo Plan Phase Objective 100X oil, N.A. 1.25, W.D. 0.23mm, F.N. 24

Zernike Phase Condenser:
   • MA913: Zernike Phase condenser with centerable phase annuli for 10X, 20X, 40X, 100X with brightfield position, dark-field stop for 40X objective, (Black-out position for epi-fluorescence on MT6000 Series only) with iris in dove tail mount (Included in Models MT5210L, MT5310L, MT5210H and MT5310H and Ergo models)

Other Zernike Components:
   • MA458/05: Centering Telescope, 30.0 mm O.D. (Included in Model MT5210L, MT5310L, MT5210H and Ergo models)
   • MA861/05: Green Interference filter (GIF), 44.0 mm diameter, unmounted (Included in MT5210L, MT5310L, MT5210H and MT5310H and Ergo models)

Brightfield Condensers:
   • MA910/10: Abbe condenser, N.A. 1.25, with centerable Phase annuli in slider for use with 20X and 40X Phase objectives, with iris diaphragm and dovetail mount
   • MA910/15: Abbe condenser, N.A. 1.25 with darkfield stop in slider for use with 20X and 40X brightfield objectives, with iris diaphragm and dovetail mount
   • MA911: Achromatic condenser, N.A. 1.25 with iris diaphragm and dovetail mount
   • MA976: Abbe condenser, N.A. 0.90 with swing out top lens, iris diaphragm and dovetail mount For use with low power scanning objective, MA830
   • MA1024: Aplanatic condenser, N.A. 1.40 with, iris diaphragm, an dovetail mount 790.00
For use with high magnification Apochromat objectives

Darkfield Oil Immersion Objectives & Condenser System:
   • MA836: Plan Semi Apo Objective 50X, N.A. 0.87, oil with iris, W.D. 0.28, F.N. 24
   • MA838: Plan Semi Apo Objective 100X, N.A. 1.25, oil with iris, W.D. 0.23, F.N. 24
   • MA914: Darkfield condenser, N.A. 1.25, dove-tail mount (with ball bearing)

Polarizer:
   • MA915: Polarizer set for MT5000 Series microscopes

Filters for use with Transmitted Light:
   • MA858/05: ND 25 Neutral density filter, 44.0mm diameter, unmounted
   • MA856/05: LB100 Blue Clear filter 44.0mm diameter, unmounted
   • MA857/05: Green filter, clear, 44.0mm diameter, unmounted
   • MA861/05: Green Interference filter,(GIF) 44.0mm diameter, unmounted 
   • MA898: Empty filter cube for excitation filter set

Stages
   • MA918L: Ceramic coated flat-top stage, 190mm x 140mm with 80mm x 52mm X-Y movement, and left hand drop-down coaxial controls
   • MA676: Attachable clinical finger assembly for MA918R and MA918L

Eyepiece Micrometers (25mm diameter for the use with MA817 SWH 10x eyepiece)
   • MA523: Cross-line reticle, 25mm diameter
   • MA506: 10mm line divided into 100 units, 25mm diameter
   • MA509: 5mm line divided into 100 units, 25mm diameter
   • MA524: 10mm square divided into 400 parts, each square 0.5 mm, 25mm diameter
   • MA510: 10mm square divided into 100 parts, each square 1.0 mm, 25mm diameter
   • MA542: Cross-line reticle with 0.1mm graduations, 25mm diameter

Stage Micrometers
   • MA285: 1mm divided into 100 units, 0.01mm
   • MA286: 0.04” divided into 40 units, 0.001”

Replacement Bulbs & Fuses
   • MA326: Spare bulb 6V 30W halogen lamp (Replacemnet bulb for transmitted light)
   • MA327: Spare 3A Fuse for Halogen illuminator
   • BA005: HBO 100W Mercury lamp (2200 Lumens, Life expectancy 200 hours)

Miscellaneous
   • MA972: Centering target for Mercury bulb alignment (Similar to a stage micrometer but with concentric circles for aligning the image of the bulb arc)
   • MA996: Adapter to connect Prior Metal Arc Lamp to Meiji MT6000 - Prior Metal Halide power and light guide required